Bloggarkiv

Exchange 2013 RCP Client Access Service krachar

Har felsökt och konstaterat vissa problem med Exchange 2013 med RPC Client Access service hos kund.

Loggboken visar följande: Först 7031, sedan 7032 och till slut flera 7011 och 5011.

7031:
The Microsoft Exchange RPC Client Access service terminated unexpectedly. It has done this 1 time(s). The following corrective action will be taken in 5000 milliseconds: Restart the service.

7032:
The Service Control Manager tried to take a corrective action (Restart the service) after the unexpected termination of the Microsoft Exchange RPC Client Access service, but this action failed with the following error:

An instance of the service is already running.

7011
a timeout (30000 milliseconds) was reached while waiting for a transaction response from the MSExchangeRPC service.

5011
A process serving application pool ‘MSExchangeRpcProxyAppPool’ suffered a fatal communication error with the Windows Process Activation Service. The process id was ‘21368’. The data field contains the error number.

Drabbade Exchange 2013 servrar kör CU1 samt CU2.

Flera olika lösningar på problemet.
1. I registret, under HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Windows NT\ lägg till DWORD ”MinimumConnectionTimeout” med Decimalvärde ”120”
2. Stäng av och ”disabla” Exchange Health Services tjänsten.
3. För virtuella maskiner: Öka CPU & Minne
4. Om du stängt av IPv6 slå omedelbart på den igen! (skall aldrig stängas av)